TEST LABS
150 kV High-Voltage Teaching Laboratory
The HVEX Teaching Laboratory brings together, in a modular set, the equipment for AC and DC applied voltage tests and lightning impulse tests, with a 150 kV step-up transformer. The hipot, fed by a motorized variac, generates the AC voltage; with the rectifier diode and the capacitor module, the circuit delivers DC voltage. In the impulse configuration, the capacitors are charged and then discharged by the adjustable-gap spheres into the front and tail resistors, which shape the wave. Voltages are measured by a resistive divider (20,000 : 1) and a damped capacitive divider, both with uncertainty below 1%. The PLC panel controls energization and automatic grounding, and the software issues reports in Portuguese, Spanish and English. Designed for universities and training centers, it lets students assemble the circuits, run the tests and explore high-voltage generation and measurement in practice — with equipment, software, warranty and support supplied by HVEX.