Transformers Condensive Bushing Monitor for Partial Discharges

Transformers Condensive Bushing Monitor for Partial Discharges

Essential in asset management, HVEX's PD Monitor is an advanced solution for power transformer monitoring, designed to detect and assess faults in high-voltage bushings and windings. Its performs online measurements of partial discharges, capacitance, and dissipation factor in condenser bushings, providing information about insulation status and facilitating preventive maintenance management, thus avoiding forced interruptions. Keywords: Partial discharge meter, capacitive bushing tap, partial discharge monitoring, partial discharges in transformers. Standards: IEC 60270

HVEX | Transformers Condensive Bushing Monitor for Partial Discharges

Technical Information

Applicable bushing model
ABB GOB; Trench, TSEA, RIP, GOE, BSP and others (Check compatibility)
Voltage Reading
-20 V to +20 V
Operating frequency for leakage current reading
2 MHz (point of 3 dB)
Simultaneous channels
4 (3 phases + 1 leakage current)
Minimum storage
128 GB

Optimize asset management with HVEX online monitoring

Power transformers are among the most important assets in the transmission and distribution networks of electrical energy. Failures in transformers are usually catastrophic and cause irreversible internal damage, as they often occur in the insulation systems of coils and bushings. The Online PD Monitor provides accurate information about the integrity of the insulation to maintenance and asset management teams, capable of measuring online partial discharges of high-voltage windings, capacitance, and dissipation factor (tan δ) of the condenser bushings of power transformers.

HVEX | Optimize asset management with HVEX online monitoring
HVEX | Benefits and Usability

Benefits and Usability

    HVEX | https://imagedelivery.net/l1XodOiUMwrotHtpvclI7Q/f950d371-1725-482e-8875-339443bad200/banner2k

    Enjoy the benefits of Shield-X

    • Free Platform

      Maintain an event history and receive real-time alerts to ensure efficient operations with Shield-X.

    • Quick fault detection

      Stay ahead of faults with fault identification through trip current overreach or di/dt variation.

    • Fast restoration

      Keep your operations flowing efficiently and minimize impacts on circuit faults.

    • Immediate alerts

      The system identifies faults and sends real-time alerts instantly, through operational logic.

    HVEX | https://imagedelivery.net/l1XodOiUMwrotHtpvclI7Q/1b941b5b-fcee-46b7-b4a9-a5e8a55cf200/banner2k

    Enjoy the benefits of PDMS

    • User-friendly interface

      Allows visualization of DNP3 points, export history to Excel, and configure connections with SCADA or RTAC.

    • Custom reports

      Allows for the automatic issuance of custom reports in different formats, such as .pdf and .doc.

    • High precision in analysis

      HVEX PDMS is software for the analysis of radio interference voltage and partial discharge measurement.

    • Test history

      Capable of controlling tests, filtering reading signals to remove noise, and managing the database.

    Various communication modalities

    It has several communication options to provide stability and speed in data transmission. The user can change the communication mode by simply disconnecting the communication board from its terminals and replacing it with one that supports the desired communication technology.

    • HVEX | ImageOptical Fiber
    • HVEX | ImageEthernet