HVEX

Command Palette

Search for a command to run...

HVEX | Surge Test — Surge Immunity Test Generator

TEST LABS

Surge Test — Surge Immunity Test Generator

The HVEX Surge Test is a combination wave generator for unidirectional surge immunity testing of electrical and electronic equipment per IEC 61000-4-5 and GB/T 17626.5. It reproduces the transient overvoltages caused by lightning and by switching in the network and applies them to the equipment under test (EUT) in a repeatable way. The set combines the control unit, the surge generator and the coupling/decoupling network (CDN), which injects the surge into the EUT power lines and protects the supply network. The generator produces a 1.2/50 µs open-circuit voltage and an 8/20 µs short-circuit current, with a 2 Ω effective impedance and peak current up to 3.3 kA. Positive, negative or alternating polarity, 1 to 999 surges with a 6 s to 999 s interval, and injection synchronized with the supply phase (0° to 359°) or asynchronous. Ideal for EMC and development laboratories that need to verify the immunity of meters, industrial equipment, tools and IT and telecom equipment before certification.

Technical Information

Grounding
Grounding resistance below 4 Ω
Temperature
15 °C to 35 °C
Relative humidity
25% to 75%
Atmospheric pressure
86 kPa to 106 kPa
Power supply
220 VAC ± 10%, 50/60 Hz

The IEC 61000-4-5 combination wave

In open circuit, the generator delivers the 1.2/50 µs voltage wave; in short circuit, the 8/20 µs current wave. The ratio between the peaks is the 2 Ω effective impedance — at 3.3 kA peak current, the corresponding voltage is 6.6 kV.

HVEX | The IEC 61000-4-5 combination wave
HVEX | Benefits and Usability

Benefits and Usability

  • HVEX | Per IEC 61000-4-5
    Per IEC 61000-4-5

    1.2/50 µs (voltage) and 8/20 µs (current) combination wave, with 2 Ω effective impedance.

  • HVEX | Up to 3.3 kA peak
    Up to 3.3 kA peak

    Short-circuit current adjustable from 0 to 3.3 kA, with ± 10% tolerance.

  • HVEX | Supply synchronization
    Supply synchronization

    Synchronous injection at any phase angle from 0° to 359°, or asynchronous mode.

  • HVEX | Programmable sequences
    Programmable sequences

    1 to 999 surges, 6 s to 999 s interval and positive, negative or alternating polarity.

Surge Test highlights

Repeatable surge immunity testing in your own laboratory.

  • HVEX | Image1.2/50 – 8/20 µs combination wave
  • HVEX | ImagePeak current up to 3.3 kA
  • HVEX | Image0° to 359° synchronous injection
  • HVEX | ImageIntegrated coupling network